Volume 14, Issue 2 (8-2020)                   2020, 14(2): 203-222 | Back to browse issues page

XML Persian Abstract Print


Download citation:
BibTeX | RIS | EndNote | Medlars | ProCite | Reference Manager | RefWorks
Send citation to:

Akbardoost J, Bidadi J. Experimental Investigation on the Effect of the Specimen Thickness on the Mode II Fracture Resistance of Rocks. Journal of Engineering Geology 2020; 14 (2) :203-222
URL: http://jeg.khu.ac.ir/article-1-2877-en.html
1- , akbardoost@khu.ac.ir
Abstract:   (4431 Views)
Introduction
Rock masses have an enormous geometrical discontinuities such as void, notch, crack and flaw. These geometrical discontinuities which play as stress concentrator, cause to reduce the load bearing capacity of rock masses. In rock masses, the crack is the most important geometrical discontinuity assessed frequently by civil, mechanical and mining engineers and researcher. The fracture mechanics which is a branch of mechanical engineering science, has been often used for investigating the cracked rock samples. The fracture toughness is one of the important parameters in the fracture mechanics which describes the resistance of materials against the crack growth. On the other hand, since orientation of cracks relative to the loading directions can be arbitrary, brittle fracture in rocks may happen due to a combination of two major fracture modes, i.e. crack opening mode (mode I) and crack sliding mode without any opening or closing the crack flanks (mode II). In order to obtain the fracture toughness of rocks, several test configurations under pure mode I have been proposed. One of the parameters that has the influence on the fracture toughness of rocks and other materials is the thickness of test sample. Previous experimental results showed that the fracture toughness of rocks increases by increasing the specimen thickness until a specific thickness. After that, the fracture toughness decreases for thicker samples until plane strain condition occurs. Then, the fracture toughness becomes a fixed value when the thickness of sample varies.
The all preceding studies have been dealt with considering the effect of specimen thickness on fracture toughness focusing only the mode I fracture toughness and there is few research concerning the thickness effect on the mode II fracture toughness of rocks. Therefore, the aim of this paper is to investigate experimentally the effect of specimen thickness on the mode II fracture toughness.
Material and methods
To investigate the thickness effect on the mode II fracture toughness of rocks, several fracture tests were conducted on the semi-circular bend (SCB) specimens. The SCB specimen is a semi-disk of radius R and thickness t including an edge crack of length a loaded under three-point bending. When the crack is along the applied load and the bottom supports are symmetric relative to vertical crack, the SCB sample is under pure mode I loading. One of the methods for achieving the mixed mode loading in SCB sample is the asymmetry distances of bottom supports from the vertical crack located at the middle of bottom edge (see Figure 1). The pure mode II in this type of SCB sample is attained at a specific distances, i.e. at specific values of S1 and S2. These values of supporting distance can be obtained from finite element analysis.

Figure 1. The schematic of SCB sample.
The fracture tests were done both on pure mode I and pure mode II, for the sake of comprehensiveness. Therefore, 32 SCB samples with 4 different thicknesses and 4 repetition for each specimen size were tested for both pure mode I and pure mode II. The specimens were cut from Ghorveh marble sheets with different thicknesses by water jet machine. Then, the specimens were cracked artificially by a high speed rotary diamond saw blade. The specimen dimensions and loading conditions are presented in Table 1. Finally, the cracked SCB samples were tested by using a 300 kN ball-screw universal test machine. Table 1 also gives the average of four fracture loads (Pf) obtained for each thickness of specimen.
Table 1. The specimen dimensions and loading conditions.
  S.D.  (N) Pf  (N) S2 (mm) S1 (mm) a (mm) t (mm) R (mm)
Pure mode I 150 3220 57 57 28.5 15 95
Pure mode II 350 4726 11 57
Pure mode I 360 6711 57 57 28.5 25 95
Pure mode II 882 9445 11 57
Pure mode I 1450 20285 57 57 28.5 50 95
Pure mode II 4179 25441 11 57
Pure mode I 4672 31810 57 57 28.5 80 95
Pure mode II 4686 36848 11 57
Results and discussion
The mode I and mode II fracture toughness (KIc and KIIc) can be calculated for SCB samples from following equations:
(1)
(2)
where Pf is fracture load, R and t are the radius and thickness of SCB sample, respectively KI* and KII* are geometry factors which depend on geometrical ratios a/R, S1/R and S2/R and independent of specimen dimensions and magnitude of applied load. These dimensionless parameters are often obtained from finite element analysis. For tested SCB samples, the values of KI* and KII* were extracted from previous studies as shown in Table 2. Substituting the fracture loads and specimen dimensions from Table 1 and the values of KI* and KII* given in Table 2 into Eqs. (1) and (2), the mode I and mode II fracture toughness were calculated as listed in Table 2. Figure 2 also shows the variations of mode I and mode II fracture toughness with respect to specimen thickness. As seen from this figure, the fracture toughness for both pure modes increases for thicker samples until a specific thickness. After that, the values of KIc and KIIc decrease by increasing the specimen thickness. For plane strain condition in which the thickness of specimen is relatively large, the values of KIc and KIIc are nearly constant.
 
 
Table 2. The dimensionless parameters KI* and KII* for tested SCB samples and their corresponding fracture toughness.
  KIIc (MPa.√m) KIc (MPa.√m) KII* KI* t R
Pure mode I 0.0 1.125 0.0 0.644 15 95
Pure mode II 0.897 0.0 0.35 0.0
Pure mode I 0.0 1.411 0.0 0.644 25 95
Pure mode II 1.075 0.0 0.35 0.0
Pure mode I 0.0 2.126 0.0 0.644 50 95
Pure mode II 1.448 0.0 0.35 0.0
Pure mode I 0.0 2.083 0.0 0.644 80 95
Pure mode II 1.311 0.0 0.35 0.0
The other point assessed in the present study is the dependency of fracture path on specimen thickness in mode II loading. It was shown that the fracture trajectory becomes more curvilinearly when the thickness of specimen increases.

Figure 2. The variations of KIc and KIIc versus the specimen thickness.
Conclusion
The effect of specimen thickness on the mode I and mode II fracture toughness of rock was investigated experimentally using the SCB specimens. The experimental results showed that the fracture toughness for both pure modes increases when the thickness of specimen increases until a specific thickness. After that, the values of KIc and KIIc decrease by increasing the specimen thickness. For plane strain condition in which the thickness of specimen is relatively large, the values of KIc and KIIc are nearly constant. Also, it is shown the crack grows more curvilinearly for thicker SCB samples../files/site1/files/142/1.pdf
 
Full-Text [PDF 731 kb]   (1289 Downloads)    
Type of Study: Review Article | Subject: Geotecnic
Received: 2019/04/15 | Accepted: 2019/05/14 | Published: 2020/08/31